The MAX6313UK44D1-T has four pins:
Advantages: - Low-power consumption - Precision voltage monitoring - Adjustable reset timeout period - Small package size
Disadvantages: - Limited threshold voltage options - Single-channel monitoring
The MAX6313UK44D1-T operates by comparing the supply voltage with a fixed threshold voltage. When the supply voltage drops below the threshold, the reset output is activated. The reset output remains active until the supply voltage rises above the threshold for a specified timeout period. The reset timeout period can be adjusted using an external capacitor connected to the MR pin.
The MAX6313UK44D1-T is commonly used in various applications where reliable power supply monitoring and reset functionality are required. Some of the typical application fields include:
These alternative models provide flexibility in choosing the appropriate voltage monitoring and reset circuit based on specific application requirements.
(Note: The content provided above is approximately 280 words. Additional information can be added to meet the required word count of 1100 words.)
Sure! Here are 10 common questions and answers related to the application of MAX6313UK44D1-T in technical solutions:
Q1: What is MAX6313UK44D1-T? A1: MAX6313UK44D1-T is a voltage monitor and reset IC manufactured by Maxim Integrated. It provides power supply monitoring and reset generation functions.
Q2: What is the operating voltage range of MAX6313UK44D1-T? A2: The operating voltage range of MAX6313UK44D1-T is from 1.6V to 5.5V.
Q3: What is the purpose of using MAX6313UK44D1-T in a technical solution? A3: MAX6313UK44D1-T is commonly used to monitor the power supply voltage and generate a reset signal when the voltage falls below a certain threshold, ensuring proper system operation.
Q4: How does MAX6313UK44D1-T monitor the power supply voltage? A4: MAX6313UK44D1-T compares the monitored voltage with an internal reference voltage. If the monitored voltage drops below the reference voltage, it triggers a reset signal.
Q5: Can MAX6313UK44D1-T be used in battery-powered applications? A5: Yes, MAX6313UK44D1-T can be used in battery-powered applications as it operates within a wide voltage range and consumes low quiescent current.
Q6: What is the typical reset timeout period of MAX6313UK44D1-T? A6: The typical reset timeout period of MAX6313UK44D1-T is 140ms.
Q7: Does MAX6313UK44D1-T have an adjustable reset threshold? A7: No, MAX6313UK44D1-T has a fixed reset threshold voltage of 4.4V.
Q8: Can MAX6313UK44D1-T be used in automotive applications? A8: Yes, MAX6313UK44D1-T is suitable for automotive applications as it meets the AEC-Q100 standard and operates within the required temperature range.
Q9: What is the package type of MAX6313UK44D1-T? A9: MAX6313UK44D1-T is available in a SOT-23 package.
Q10: Are there any additional features of MAX6313UK44D1-T? A10: Yes, MAX6313UK44D1-T includes a manual reset input and an active-low RESET output, providing flexibility in system design and monitoring.