Maaaring representasyon ang larawan.
Tingnan ang mga detalye para sa mga detalye ng produkto.
P51-1500-A-Y-D-20MA-000-000

P51-1500-A-Y-D-20MA-000-000

Product Overview

Category

The P51-1500-A-Y-D-20MA-000-000 belongs to the category of pressure sensors.

Use

It is used to measure and monitor pressure in various industrial and commercial applications.

Characteristics

  • High accuracy
  • Wide operating temperature range
  • Compact size
  • Robust construction

Package

The sensor is typically packaged in a durable housing suitable for industrial environments.

Essence

The essence of the P51-1500-A-Y-D-20MA-000-000 lies in its ability to provide precise and reliable pressure measurements.

Packaging/Quantity

The sensor is usually packaged individually and is available in varying quantities based on customer requirements.

Specifications

  • Pressure Range: 0-1500 psi
  • Output: 4-20 mA
  • Operating Temperature: -40°C to 125°C
  • Supply Voltage: 10-30 VDC
  • Accuracy: ±0.5% full scale

Detailed Pin Configuration

The detailed pin configuration of the P51-1500-A-Y-D-20MA-000-000 is as follows: 1. Power Supply 2. Ground 3. Signal Output 4. Not Connected

Functional Features

  • High precision measurement
  • Compatibility with various media
  • Long-term stability
  • Overpressure protection

Advantages

  • Accurate and reliable pressure measurement
  • Suitable for harsh environments
  • Low power consumption
  • Easy integration into existing systems

Disadvantages

  • Limited pressure range
  • May require additional protection in extreme conditions

Working Principles

The P51-1500-A-Y-D-20MA-000-000 operates on the principle of strain gauge technology, where changes in pressure cause deformation in the sensing element, resulting in a proportional change in electrical resistance. This change is then converted into an output signal that corresponds to the applied pressure.

Detailed Application Field Plans

The P51-1500-A-Y-D-20MA-000-000 is commonly used in the following applications: - Hydraulic systems - Industrial machinery - Process control - HVAC systems - Automotive testing

Detailed and Complete Alternative Models

Some alternative models to the P51-1500-A-Y-D-20MA-000-000 include: - P51-1000-A-Y-D-20MA-000-000 - P51-2000-A-Y-D-20MA-000-000 - P51-1500-B-Y-D-20MA-000-000

In conclusion, the P51-1500-A-Y-D-20MA-000-000 pressure sensor offers high accuracy, reliability, and compatibility, making it a valuable component in various industrial and commercial applications.

Word Count: 342

Maglista ng 10 karaniwang tanong at sagot na nauugnay sa aplikasyon ng P51-1500-A-Y-D-20MA-000-000 sa mga teknikal na solusyon

  1. What is the P51-1500-A-Y-D-20MA-000-000 used for?

    • The P51-1500-A-Y-D-20MA-000-000 is a pressure transducer commonly used for measuring and monitoring pressure in various technical applications.
  2. What is the operating range of the P51-1500-A-Y-D-20MA-000-000?

    • The operating range of the P51-1500-A-Y-D-20MA-000-000 is typically from 0 to 1500 psi, making it suitable for a wide range of pressure measurement needs.
  3. What are the output options for the P51-1500-A-Y-D-20MA-000-000?

    • The P51-1500-A-Y-D-20MA-000-000 typically provides a 4-20mA output signal, which is commonly used in industrial control and monitoring systems.
  4. Is the P51-1500-A-Y-D-20MA-000-000 suitable for use in harsh environments?

    • Yes, the P51-1500-A-Y-D-20MA-000-000 is designed to withstand harsh environmental conditions, including high vibration and extreme temperatures.
  5. Can the P51-1500-A-Y-D-20MA-000-000 be used for liquid as well as gas pressure measurement?

    • Yes, the P51-1500-A-Y-D-20MA-000-000 is suitable for measuring both liquid and gas pressures, making it versatile for various applications.
  6. What is the accuracy of the P51-1500-A-Y-D-20MA-000-000?

    • The P51-1500-A-Y-D-20MA-000-000 typically offers high accuracy, often within ±0.25% of full scale, ensuring precise pressure measurements.
  7. Is the P51-1500-A-Y-D-20MA-000-000 compatible with standard industrial interfaces?

    • Yes, the P51-1500-A-Y-D-20MA-000-000 is often compatible with standard industrial interfaces, allowing for seamless integration into existing systems.
  8. What are the typical applications for the P51-1500-A-Y-D-20MA-000-000?

    • Typical applications for the P51-1500-A-Y-D-20MA-000-000 include hydraulic systems, process control, industrial machinery, and automotive testing, among others.
  9. Does the P51-1500-A-Y-D-20MA-000-000 require special calibration or maintenance?

    • The P51-1500-A-Y-D-20MA-000-000 may require periodic calibration and maintenance to ensure continued accuracy and performance, as per manufacturer guidelines.
  10. Are there any special installation considerations for the P51-1500-A-Y-D-20MA-000-000?

    • Proper mounting orientation, electrical connections, and protection from excessive vibration or shock are important considerations for installing the P51-1500-A-Y-D-20MA-000-000 to ensure optimal performance.