INA126U/2K5G4

INA126U/2K5G4

Product Overview

  • Category: Integrated Circuit (IC)
  • Use: Instrumentation Amplifier
  • Characteristics: High precision, low noise, low power consumption
  • Package: SOIC (Small Outline Integrated Circuit)
  • Essence: Differential amplifier with high common-mode rejection ratio (CMRR)
  • Packaging/Quantity: Tape and Reel, 2500 units per reel

Specifications

  • Supply Voltage: ±2.25V to ±18V
  • Input Offset Voltage: ±150µV (maximum)
  • Input Bias Current: ±50nA (maximum)
  • Gain Bandwidth Product: 1MHz (typical)
  • Input Common-Mode Voltage Range: -Vs + 1.8V to +Vs - 1.8V
  • Operating Temperature Range: -40°C to +85°C

Pin Configuration

The INA126U/2K5G4 has a total of 8 pins:

  1. REF: Reference voltage input
  2. RG: Gain resistor connection
  3. V+: Positive supply voltage
  4. IN+: Non-inverting input
  5. IN-: Inverting input
  6. V-: Negative supply voltage
  7. OUT: Output
  8. NC: No connection

Functional Features

  • High common-mode rejection ratio (CMRR) of 120dB (minimum)
  • Low input offset voltage and bias current for accurate measurements
  • Wide input common-mode voltage range for versatile applications
  • Low power consumption for energy-efficient operation
  • Rail-to-rail output swing for maximum dynamic range

Advantages and Disadvantages

Advantages: - High precision amplification of differential signals - Excellent rejection of common-mode noise - Versatile operating voltage range - Low power consumption

Disadvantages: - Limited gain bandwidth product compared to some other instrumentation amplifiers - Requires external gain resistor for setting the desired amplification level

Working Principles

The INA126U/2K5G4 is an integrated circuit that functions as an instrumentation amplifier. It amplifies the difference between its non-inverting (IN+) and inverting (IN-) inputs while rejecting common-mode signals. The gain of the amplifier is determined by an external gain resistor connected to the RG pin.

Detailed Application Field Plans

The INA126U/2K5G4 finds applications in various fields, including:

  1. Biomedical instrumentation: ECG (Electrocardiogram), EEG (Electroencephalogram), EMG (Electromyogram) amplification
  2. Industrial process control: Signal conditioning for sensors and transducers
  3. Strain gauge amplification: Load cells, pressure sensors, force measurement
  4. Temperature measurement: Thermocouples, RTDs (Resistance Temperature Detectors)
  5. Data acquisition systems: Precise signal amplification for accurate measurements

Detailed and Complete Alternative Models

  1. AD620: Instrumentation amplifier with similar specifications and pin configuration
  2. INA128: Higher precision instrumentation amplifier with increased gain bandwidth product
  3. AD8221: Low power instrumentation amplifier with rail-to-rail output swing

These alternative models offer similar functionality and can be considered based on specific application requirements.

Word count: 314 words

Maglista ng 10 karaniwang tanong at sagot na nauugnay sa aplikasyon ng INA126U/2K5G4 sa mga teknikal na solusyon

  1. What is the typical application of INA126U/2K5G4?
    - The typical application of INA126U/2K5G4 is in precision instrumentation and sensor amplification.

  2. What is the input voltage range of INA126U/2K5G4?
    - The input voltage range of INA126U/2K5G4 is typically ±10V.

  3. Can INA126U/2K5G4 be used for bridge sensor measurements?
    - Yes, INA126U/2K5G4 is suitable for bridge sensor measurements due to its high precision and low noise characteristics.

  4. What is the gain accuracy of INA126U/2K5G4?
    - The gain accuracy of INA126U/2K5G4 is typically 0.05%.

  5. Is INA126U/2K5G4 suitable for low-power applications?
    - Yes, INA126U/2K5G4 is suitable for low-power applications as it has a low quiescent current.

  6. Can INA126U/2K5G4 operate with a single power supply?
    - Yes, INA126U/2K5G4 can operate with a single power supply, making it suitable for portable and battery-powered applications.

  7. What is the common-mode rejection ratio (CMRR) of INA126U/2K5G4?
    - The CMRR of INA126U/2K5G4 is typically 100dB.

  8. Does INA126U/2K5G4 have built-in EMI filtering?
    - Yes, INA126U/2K5G4 has built-in EMI filtering to minimize electromagnetic interference.

  9. Can INA126U/2K5G4 be used in medical instrumentation?
    - Yes, INA126U/2K5G4 is commonly used in medical instrumentation due to its high precision and low noise performance.

  10. What is the temperature range for operation of INA126U/2K5G4?
    - INA126U/2K5G4 is designed to operate over a wide temperature range, typically from -40°C to 125°C.